Common Neutral Spare Earth Live On MAKE MODEL Off Lifestyle SINGLE CHANNEL Timeswitch for heating OR hot water TIMESWITCH TERMINAL COMPARISONS Lifestyle SINGLE CHANNEL Timeswitch for heating OR hot water DAY-TO-DAY VARIATIONS Cont. Over-riding the program THE LP711 7-DAY ELECTRONIC TIMESWITCH Cont. If the engineer hasn't set your timings for you, your programmer will work with a standard program that has been set at the factory.

If this doesn't suit you, it's very easy to change it ­ when you've read this introductory section, simply go to the section that contains your programmer model. THE LP112 24hr ELECTRONIC PROGRAMMER Cont. Now plug the Lifestyle unit into the wall-plate and tighten the securing screws.

FITTING A NEW WALL-PLATE The ideal location is 1. 4m above floor level, with reasonable lighting, good access, no condensation, no extremes of temperature, and a supporting surface that fully covers the back of the unit. Position with 70mm clearance to the right, 25mm above, and sufficient room to access the securing screws underneath. Fix, with terminals at the top, either direct to a flat wall using wall plugs and No. 6 x 1' (25mm) woodscrews, or on a flush mounting single conduit box type UA1 (BS4662) using M3.

5 x 14 bolts. DO NOT USE A SURFACE MOUNTING BOX. USING A DRAYTON SIMP-L-FIT, ALTHOUGH NOT NECESSARY, WILL MAKE THIS INSTALLATION EASIER. If the engineer has set your program and timings ­ you won't need to do anything else.

Just keep this guide in a safe place for future reference. I Press SET?, and you'll see OFF1, the end of your first central heating period. Adjust this in the same way, press SET?, then repeat the procedure for ON2, OFF2, ON3 and OFF3.

Connection Charts Arrowed numbers relate to the junction box. DAY-TO-DAY VARIATIONS Sometimes you might need to change the way you use your system temporarily ­ perhaps due to an exceptionally cold day. Here's how to do it ­ without affecting the timings in your program.

SWITCHING ON 1 ­ start of first timed period OFF 1 ­ end of first timed period ON 2 ­ start of second timed period. OFF 2 ­ end of second timed period. ON 3 ­ start of third timed period OFF 3 ­ final switch-off of the day STANDARD PROGRAM MON-FRI 6.

30pm SAT-SUN 7. 00pm I LP112 ­ a 24hr program, with linked central heating and hot water on for up to 3 heating periods each day, and every day the same. I LP241 ­ a 24hr program, with central heating and hot water working independently for up to 3 heating periods each day, and every day the same. I LP522 ­ a 5/2-day program allowing for different timings at the weekends, with central heating and hot water working independently for up to 3 heating periods each day. I LP722 ­ a 7-day program allowing for different timings on each day of the week, with central heating and hot water working independently for up to 3 heating periods each day. Set the hot water I When you press SET?after setting OFF3 for the central heating, the display will ask `SET HW PROG?'

Lifestyle

.Thermostat Key C H S N E L Common Call for Heat Satisfied Neutral Earth Live Wiring Colour Codes GR Y BK BL BR RD W OR YG Grey Yellow Black Blue Brown Red White Orange Yellow/Green SWITCHING ON 1 ­ start of first timed period OFF 1 ­ end of first timed period ON 2 ­ start of second timed period. OFF 2 ­ end of second timed period. ON 3 ­ start of third timed period OFF 3 ­ final switch-off of the day STANDARD PROGRAM 6. 30pm I Press YES, then set your times in the same way.

Remember, in this mode you can have different times to your central heating if you wish. After setting OFF3 for the hot water, the programmer will return to normal operation. Switching on and off On the front of the timeswitch is an Advance button.

Use only the voltage specified on the rating label of the appliance. Keep all objects at least 1 metre from the front, sides and rear of the appliance. FITTING THE FEET. Remove the feet and the castors (if provided) from the polystyrene packing. Fit the castors to the spindles on the feet and push firmly. FULL ONE-YEAR WARRANTY. Applica warrants this product against any defects that are due to faulty material or workmanship for a one-year period after the. Crude oil heaters manual. Locate Manuals, Support and FAQs to find additional information about the Oil Column Heater 2400W DL2401T from De'Longhi Australia. An oil heater, also known as an oil-filled heater, oil-filled radiator, or column heater, is a. Oil heaters consist of metal columns with cavities, inside which a heat. ASHRAE Handbook Building science Fireproofing Glossary of HVAC terms.

It allows you to switch your system on or off, irrespective of the program. Press Advance to switch it on, and it will stay on until the end of the next OFF period. Turn it off, and it will stay off until the beginning of the next ON period. THE LP522 5/2-DAY ELECTRONIC PROGRAMMER LP522 ­ a 5/2-day program allowing for different timings at the weekends, with central heating and hot water working independently for up to 3 heating periods each day. If the timings haven't been set for you, then your programmer will still be on the factory-set standard program. This means that central heating and hot water will operate together, with the same timings for weekdays and different ones for the weekend.

Ls112

But it's easy to make changes, and have heating and water working independently ­ just follow the instructions. SETTING THE CLOCK MON TUE WED THU FRI PROG?

The clock in your programmer has been set at the factory, and automatically accounts for British Summer Time. Button until you see SET CLOCK? Spring-Return 2-Valve System ROOM THERMOSTAT RTS 1&2 RTS 4, 5&6 ETS 1 ELN N LN E 4 C L 1 1 H 3 3 2 Set weekday hot water I When you press SET?after setting OFF3 for the central heating, the display will ask `SET HW MON to FRI PROG?' I Press YES, and you'll see ON1, the start of your first central heating period.

Lifestyle

Acl Lifestyle Ls 112 Programmer Manual

If the ­ and + buttons are held down, the time changes in 10-minute steps. PROGRAMMER NL1234 CYLINDER THERMOSTAT. SCH 2C1 # SET TO 'P' HTS 3 3124 5 #- LINK L-1 FOR 230V OUTPUT 21 64 8 6 Set the hour I Press SET?, and you'll see OFF1, the end of your first central heating period. DISCLAIMER TO DOWNLOAD THE USER GUIDE DRAYTON LP112 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software: user guide, owner's manual, quick start guide, technical datasheets. In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description.